Description
Item | Details |
---|---|
Description | S220-24P4X (24*10/100/1000BASE-T ports(400W PoE+), 4*10GE SFP+ ports, built-in AC power) |
Part Number | 98012376 |
Model | S220-24P4X |
First supported version | V600R023C00 |
Basic Information | |
Part Number |
98012376 |
Model |
eKitEngine S220-24P4X |
Description |
S220-24P4X (24*10/100/1000BASE-T ports(400W PoE+), 4*10GE SFP+ ports, built-in AC power) |
Technical Specifications | |
Chassis material |
Metal |
Height [mm] |
43.6 mm |
Depth [mm] |
220.0 mm |
Wide [mm] |
442.0 mm |
Chassis height [U] |
1 |
Weight with packaging [kg(lb)] |
3.79 kg (8.36 lb) |
Weight without packaging [kg(lb)] |
2.92 kg (6.44 lb) |
Maximum power consumption [W] |
- Without PoE: 44.35 W - Full PoE load: 485.91 W (PoE: 400 W) |
Typical power consumption [W] |
37.12 |
Heat dissipation mode |
Air cooling for heat dissipation, intelligent fan speed adjustment |
Maximum heat dissipation [BTU/hour] |
- Without PoE: 151.32 - Full PoE load: 1657.92 |
Typical heat dissipation [BTU/hour] |
126.65 |
Power supply mode |
AC built-in |
Input voltage range [V] |
- AC input: 90 V AC to 290 V AC; 45 Hz to 65 Hz - High-voltage DC input: 190 V DC to 290 V DC |
Rated input voltage [V] |
- AC input: 100 V AC to 240 V AC, 50/60 Hz - High-voltage DC input: 240 V DC |
Maximum input current [A] |
6 A |
Number of power slots |
0 |
Number of card slots |
0 |
Memory |
2 GB |
Flash memory |
Physical space: 1 GB |
Redundant power supply |
Not supported |
Types of fans |
Built-in |
Noise at normal temperature (acoustic power) [dB(A)] |
49.3 |
Noise at normal temperature (acoustic pressure) [dB(A)] |
37.3 |
Airflow direction |
Air intake from left and front, air exhaustion from right |
Storage temperature [°C(°F)] |
–40°C to +70°C (–40°F to +158°F) |
Long-term operating temperature [°C(°F)] |
-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] |
When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). Devices cannot start when the temperature is lower than 0°C (32°F). |
Long-term operating relative humidity [RH] |
5% RH to 95% RH (non-condensing) |
Storage altitude [m(ft.)] |
0-5000 m (0-16404 ft.) |
Long-term operating altitude [m(ft.)] |
0–5000 m (0–16404 ft.) |
MTBF [year] |
60.18 |
MTTR [hour] |
2 |
Availability |
> 0.99999 |
Maximum number of physical ports on the entire device |
28 |
Maximum number of 100GE ports |
0 |
Maximum number of 40GE ports |
0 |
Maximum number of 25GE ports |
0 |
Maximum number of 10GE ports |
4 |
Maximum number of GE ports |
28 |
Maximum number of FE ports |
24 |
USB |
Not supported |
Console port |
RJ45 |
Eth Management port |
Not supported |
Service port surge protection [kV] |
Common mode: ±7 kV |
Power supply surge protection |
Differential mode: ±6 kV; common mode: ±6 kV |
RPS input |
Not supported |
PoE |
Supported |
With 3 years warranty .
https://support.huawei.com/enterprise/en/doc/EDOC1100335757/30cedc26/s220-24p4x
Call Us or WhatsApp For confirm Pricing and stock availability.
Reviews
There are no reviews yet.